NDT Supplies & Accessories

Non-destructive Testing (NDT) is the examination of an object with technology that does not affect the object's future usefulness. The term “NDT” includes many methods that can detect internal or external imperfections (i.e. crack and flaws). This section includes Visible and Fluorescent Penetrant Inspection materials for surface inspection and Magnetic Particle Inspection equipment and materials for inspection of surface and subsurface imperfections.

Spotcheck® Red Dye Liquid Penetrants
Instructions for Use
Material Selection Guide
Portable Kits
Accessories

 

Magnaflux® / Magnaglo® Magnetic Particle Inspection
Instructions for Use
Material Selection Guide

Portable Kits

Accessories

Zyglo® Fluorescent Penetrant Inspection
Instructions for Use
Material Selection Guide

Portable Kits

Accessories

 

Daraclean® Aqueous Cleaners
Material Selection Guide

Black Lights & New Products
Lamps, Replacement Bulbs, Accessories, Meters

MagnaPure - Penetrant Wastewater Treatment System
New Products

 

 

Instructions for Spotcheck® Red Dye Liquid Penetrants

1 2 3 4 5
Instruction pictures read left to right
  1. Preclean inspection area. Spray on cleaner. Wipe off with cloth.
  2. Apply Penetrant. Allow short penetration period.
  3. Spray cleaner on wiping cloth and wipe surface clean.
  4. Spray on a thin, uniform film of developer.
  5. Inspect. Defects will show as bright red lines in white developer background.

Spotcheck® Red Dye Liquid Penetrants
Material Selection Guide
Portable Kits
Accessories

Return to top

 

 

Instructions for Zyglo® Fluorescent Penetrant Inspection

1 2 3 4 5
Instruction pictures read left to right
  1. Preclean inspection area. Spray on cleaner. Wipe off with cloth.
  2. Apply penetrant. Allow short penetration period.
  3. Spray cleaner on wiping cloth and wipe surface clean.
  4. Apply a thin film of developer. Allow short developing period.
  5. Inspect under black light. Cracks and lack of bond will show as glowing lines, porosity will show as spots.

Zyglo® Fluorescent Penetrant Inspection
Material Selection Guide

Portable Kits

Accessories

Return to top

 

 

Instructions for Magnaflux® / Magnaglo® Magnetic Particle Inspection

1 2 3 4 5
Instruction pictures read left to right
  1. Preclean inspection area. Spray on cleaner. Wipe off with cloth.
  2. Place yoke on test piece perpendicular to direction of suspected cracks.
  3. Energize yoke.
  4. Apply magnetic powder or prepared bath while yoke is energized.
  5. Indications will form immediately.

Magnaflux® / Magnaglo® Magnetic Particle Inspection
Material Selection Guide

Portable Kits

Accessories

 

Return to top

 

 

Products & Services:

NDT Supplies & Accessories • Lubricants, Solvents & Plastic Coatings • Adhesives & Sealants
Golf Club Assembly Products • Custom/Contract Packaging •
 Manufacturers We Represent

 

 

About UsProducts & ServicesContact UsQuick QuoteOrder FormHome

 

V.O. Baker Company
Phone (Toll free - U. S. only): (800) 321-3572
Phone (Outside the U. S.):  (440) 255-1020
Fax: (440) 255-1470